AC Power Supply PCR-LE series

AC Power Supply PCR-LE2 series

AC Power Supply PCR-M series

Commnunication Interface Mannual


 

Command (Subsystem)

SOURce subsystem

CURR Sets the AC current upper limit
CURR:OFFS Sets the DC current upper limit
CURR:PEAK Sets the peak limit of the positive electric potential
CURR:PEAK:LOW Sets the peak limit of the negative electric potential
CURR:PROT:OCP2:TIME Sets the time that must elapse after the internal semiconductor protection is activated before an alarm is generated
CURR:PROT:STAT Action that is performed when the current limit is exceeded
CURR:PROT:TRIP:TIME Sets the time until the protection function trips when the current limit is exceeded
FREQ Sets the frequency
FREQ:LIM Sets the frequency upper limit
FREQ:LIM:LOW Sets the frequency lower limit
FREQ:MODE Sets the trigger function control of the frequency setting
FREQ:SYNC Turns the synchronization function on and off
FREQ:SYNC:PHASE:DEL Sets the synchronization delay phase angle of the synchronization function
FREQ:TRIG Sets the frequency that will be set when a trigger is received
VOLT Sets the AC voltage
VOLT:LIM Sets the AC voltage upper limit
VOLT:LIM:LOW Sets the AC voltage lower limit
VOLT:MODE Sets the trigger function control of the AC voltage setting
VOLT:OFFS Sets the DC voltage
VOLT:OFFS:LIM Sets the DC voltage upper limit
VOLT:OFFS:LIM:LOW Sets the DC voltage lower limit
VOLT:OFFS:MODE Sets the trigger function control of the DC voltage setting
VOLT:OFFS:PROT:LEV

Sets the OVP value to use to judge averaged voltage measurements

VOLT:OFFS:PROT:LEV:LOW

Sets the UVP value to use to judge averaged voltage measurements

VOLT:OFFS:TRIG Sets the DC voltage that will be set when a trigger is received
VOLT:PROT:LEV

Sets the OVP value used to judge rms voltage measurements

VOLT:PROT:LEV:LOW

Sets the UVP value used to judge rms voltage measurements

VOLT:RANG Sets the voltage range
VOLT:TRIG Sets the AC voltage that will be set when a trigger is received
VOLT:VCC Sets the internal Vcc voltage
VOLT:VCC:MODE Sets the Vcc operating condition
WAVE:BANK Specifies the number of the waveform bank that you want to execute
WAVE:BANK:TRIG Sets the number of the waveform bank that will be set when a trigger is received
WAVE:BANK:MODE Sets the trigger function control of the number of the waveform bank
WAVE:BANK:TYPE Queries the output waveform type
WAVE:EDIT:PCL Sets the special waveform to the sine wave or a peak-clipped waveform, and sets the crest factor
WAVE:EDIT:USER:DATA:POIN Sets a user-defined waveform
WAVE:EDIT:SIN Sets the special waveform to the sine wave

SOURce subsystem
(Single-phase, three-wire output/ Three-phase output)

CURR{1|2|3} Sets the AC current upper limit of each phase
CURR{1|2|3}:OFFS Sets the DC current upper limit of each phase
CURR{1|2|3}:PEAK Sets the peak limit of the positive electric potential of each phase
CURR{1|2|3}:PEAK:LOW Sets the peak limit of the negative electric potential of each phase
VOLT{1|2|3} Sets the AC voltage of each phase
VOLT{1|2|3}:TRIG Sets the AC voltage of each phase that will be set when a trigger is received
VOLT:LINE Sets the AC line voltage
VOLT{1|2|3}:OFFS Sets the DC voltage of each phase
VOLT{1|2|3}:OFFS:TRIG Sets the DC voltage of each phase that will be set when a trigger is received
VOLT:OFFS:LINE Sets the DC line voltage (2P05-PCR-LE only)
WAVE{1|2|3}:EDIT:USER:DATA:POIN Sets a user-defined waveform of each phase

SOURce subsystem (Analog signal operation)

FUNC:SOUR Sets the signal source (EX05-PCR-LE only)
VOLT:EXT:SOUR Sets the signal source (EX06-PCR-LE only)

>top

Command (function search)

Command (ABC search)

Command (Sub-system search)

Register

Appendix

Tutorial

AC power supply  PCR-M seriesAC Power Supply PCR-LE series
Communication Interface Manual

AC power supply  PCR-M seriesAC Power Supply PCR-LE2 series
Communication Interface Manual

AC power supply  PCR-M seriesAC Power Supply PCR-M series
Communication Interface Manual