WAVE:EDIT:PCL
Sets the crest factor of the waveform bank whose number you specify. To configure sine waves, use the WAVE:EDIT:SIN command.
This command is valid in AC mode and AC+DC mode (OUTP:COUP AC|ACDC).
This command is not valid when the synchronization function is in use (FREQ:SYNC ON).
If you specify the waveform bank (using WAVE:BANK) and then turn the output on (using OUTP ON), you cannot specify the same waveform bank number with this command (the command will not be valid).
Command
[SOURce:]WAVE:EDIT:PCLip <BANK_NR1>,{<PCLIP_numeric>|MINimum|MAXimum}
[SOURce:]WAVE:EDIT:PCLip? <BANK_NR1>[,{MINimum|MAXimum}]
Parameter (BANK_NR1)
Value | 1 to 63 | Waveform bank number |
Parameter (PCLIP_numeric)
Value | 1.1 to 1.40 | Crest factor of a peak-clipped waveform (1.40 by default) |
Response