WAVE:EDIT:PCL

Sets the crest factor of the waveform bank whose number you specify. To configure sine waves, use the WAVE:EDIT:SIN command.

This command is valid in AC mode and AC+DC mode (OUTP:COUP AC|ACDC).

This command is not valid when the synchronization function is in use (FREQ:SYNC ON).

If you specify the waveform bank (using WAVE:BANK) and then turn the output on (using OUTP ON), you cannot specify the same waveform bank number with this command (the command will not be valid).

Command

[SOURce:]WAVE:EDIT:PCLip <BANK_NR1>,{<PCLIP_numeric>|MINimum|MAXimum}

[SOURce:]WAVE:EDIT:PCLip? <BANK_NR1>[,{MINimum|MAXimum}]

Parameter (BANK_NR1)

Value 1 to 63 Waveform bank number

Parameter (PCLIP_numeric)

Value 1.1 to 1.40 Crest factor of a peak-clipped waveform
(1.40 by default)

Response

Returns the crest factor in NR3 format in response to WAVE:EDIT:PCL? <BANK>.