VOLT:PROT:LEV (PCR-LE/ PCR-LE2 only)
Sets the OVP value used to judge rms voltage measurements.
This command is valid in AC or AC+DC mode (OUTP:COUP AC|ACDC).
For single-phase three-wirećand three-phse (PCR-LE optional), set this value with the phase voltage.
Command
[SOURce:]VOLTage:PROTection:LEVel[:UPPer] {<numeric>|MINimum|MAXimum}
[SOURce:]VOLTage:PROTection:LEVel[:UPPer]? [{MINimum|MAXimum}]
Parameter
Value | 0 to 474.1 (474.1 by default) A SCPI error (-222, "Data out of range") occurs if outside the range. |
Unit | V |
For the setting that is applied when *RST is sent, see this table
For the setting that is applied when *RST is sent, see this table
For the setting that is applied when *RST is sent, see this table
Response
Response
Returns the OVP value in NR3 format in response to VOLT:PROT:LEV?.