AC Power Supply PCR-LE series

AC Power Supply PCR-LE2 series

AC Power Supply PCR-M series

Commnunication Interface Mannual


 

Command (Function)

Triggered Control of Output

The second level nodes are SEQuence[1] and TRANsient. Regardless of which node you use, the PCR operates in the same way when it receives the commands.

-> Tutorial

 

VOLT:TRIG Sets the AC voltage that will be set when a trigger is received
VOLT{1|2|3}:TRIG Sets the AC voltage of each phase that will be set when a trigger is received
VOLT:MODE Sets the trigger function control of the AC voltage setting
VOLT:OFFS:TRIG Sets the DC voltage that will be set when a trigger is received
VOLT{1|2|3}:OFFS:TRIG Sets the DC voltage of each phase that will be set when a trigger is received
VOLT:OFFS:MODE Sets the trigger function control of the DC voltage setting
FREQ:TRIG Sets the frequency that will be set when a trigger is received
FREQ:MODE Sets the trigger function control of the frequency setting
WAVE:BANK:TRIG Sets the number of the waveform bank that will be set when a trigger is received
WAVE:BANK:MODE Sets the trigger function control of the number of the waveform bank
TRIG:SOUR Sets the trigger source of the sequence 1 group
INIT Starts the trigger function of the sequence 1 group
INIT:NAME Starts the trigger function of the specified sequence group
TRIG Sequence 1 group software trigger
ABOR Aborts the trigger function

>top

Command (function search)

Command (ABC search)

Command (Sub-system search)

Register

Appendix

Tutorial

AC power supply  PCR-M seriesAC Power Supply PCR-LE series
Communication Interface Manual

AC power supply  PCR-M seriesAC Power Supply PCR-LE2 series
Communication Interface Manual

AC power supply  PCR-M seriesAC Power Supply PCR-M series
Communication Interface Manual