AC Power Supply PCR-LE series

AC Power Supply PCR-LE2 series

AC Power Supply PCR-M series

Commnunication Interface Mannual


 

VOLT:VCC

Sets the internal Vcc voltage.

This command is valid when the Vcc operating conditions function is fixed (VOLT:VCC:MODE MAN).

Command

[SOURce:]VOLTage:VCC[:LEVel] {<numeric>|MINimum|MAXimum}

[SOURce:]VOLTage:VCC[:LEVel]? [{MINimum|MAXimum}]

Parameter

Value

0 to 431.0 (431.0 by default)
 
A SCPI error (-222, "Data out of range") occurs if outside the range.

Unit V

For the setting that is applied when *RST is sent, see this table

For the setting that is applied when *RST is sent, see this table

For the setting that is applied when *RST is sent, see this table

Response

Response

Returns the Vcc voltage in NR3 format in response to VOLT:Vcc?.

Command (function search)

Command (ABC search)

Command (Sub-system search)

Register

Appendix