VOLT:EXT:SOUR
Select whether to control the AC voltage output using an external signal.
This command is valid in Varying the voltage of the output AC waveform using DC signals (optional).
Single-phase three-wire output or Three-phase output (PCR-LE optional): Sets the signal source of all phases at once.
This is valid in AC mode and AC+DC mode (OUTP:COUP AC|ACDC).
This is valid in DC mode and AC+DC mode (OUTP:COUP DC|ACDC).
This command is not valid when the output is on (OUTP ON).
Command
[SOURce:]VOLTage:EXTernal:SOURce {NONE|VOLTage}
[SOURce:]VOLTage:EXTernal:SOURce?
Parameter
Vallue | NONE | Do not control the AC voltage using an external signal |
VOLTage | Control the AC voltage using an external signal |
For the setting that is applied when *RST is sent, see this table
For the setting that is applied when *RST is sent, see this table
For the setting that is applied when *RST is sent, see this table
Response
Response
Returns the signal source in character data format in response to VOLT:EXT:SOUR?.