AC Power Supply PCR-LE series

AC Power Supply PCR-LE2 series

AC Power Supply PCR-M series

Commnunication Interface Mannual


 

VOLT:OFFS:TRIG

Sets the target DC voltage when INIT/INIT:NAME TRAN and a software trigger are sent.

This command is valid in DC mode and AC+DC mode (OUTP:COUP DC|ACDC).

If the EX05-PCR-LE is in use (optional) and the signal source is set to external signal source (FUNC:SOUR EXT), this command is invalid.

During two-phase output(SYST:CONF:TPH:MODE ON), or single-phase, three-wire output (optional), the value is assigned to the U phase. The V phase is automatically set to the same amplitude as the U phase but with opposite polarity.

Command

[SOURce:]VOLTage[0]:OFFSet:TRIGgered {<numeric>|MINimum|MAXimum}

[SOURce:]VOLTage[0]:OFFSet:TRIGgered? [{MINimum|MAXimum}]

Parameter

Value DC mode, L range: -215.5 to 215.5
DC mode, H range: -431.0 to 431.0
AC+DC mode, L range: This can only be set when the AC and DC voltages are within the settable ranges defined by the voltage limits and the AC+DC waveform peak is between -215.5 V and 215.5 V.
AC+DC mode, H range: This can only be set when the AC and DC voltages are within the settable ranges defined by the voltage limits and the AC+DC waveform peak is between -431 V and 431 V.

A SCPI error (-222, "Data out of range") occurs if outside the range.
The default value is 0.
Unit V
Value DC mode, 135V range: -194.0 to 194.0
DC mode, 270V range: -388.0 to 388.0
AC+DC mode, 135V range: This can only be set when the AC and DC voltages are within the settable ranges defined by the voltage limits and the AC+DC waveform peak is between -194 V and 194 V.
AC+DC mode, 270V range: This can only be set when the AC and DC voltages are within the settable ranges defined by the voltage limits and the AC+DC waveform peak is between -388 V and 388 V.

A SCPI error (-222, "Data out of range") occurs if outside the range.
The default value is 0.
Unit V

For the setting that is applied when *RST is sent, see this table

For the setting that is applied when *RST is sent, see this table

For the setting that is applied when *RST is sent, see this table

Response

Response

Returns the target value to which the DC voltage is to change using a trigger in NR3 format in response toVOLT:OFFS:TRIG?.

In case of the two-phase output, VOLT:OFFS:TRIG? returns a comma-separated list of the target value to which the DC voltage <NR3> for U and V phases.

In case of the three-phase output, VOLT:OFFS:TRIG? returns a comma-separated list of the target value to which the DC voltage <NR3> for U, V, and W phases.

Command (function search)

Command (ABC search)

Command (Sub-system search)

Register

Appendix

Tutorial

AC power supply  PCR-M seriesAC Power Supply PCR-LE series
Communication Interface Manual

AC power supply  PCR-M seriesAC Power Supply PCR-LE2 series
Communication Interface Manual

AC power supply  PCR-M seriesAC Power Supply PCR-M series
Communication Interface Manual