AC Power Supply PCR-LE series

AC Power Supply PCR-LE2 series

AC Power Supply PCR-M series

Commnunication Interface Mannual


 

CURR:OFFS

Sets the DC current upper limit.

This is valid in DC mode (OUTP:COUP DC).

This is valid in DC mode and AC+DC mode (OUTP:COUP DC|ACDC).

Single-phase three-wire output or Three-phase output (optional): Sets the AC current upper limit of all phases at once.

Command

[SOURce:]CURRent:OFFSet[:IMMediate] {<numeric>|MINimum|MAXimum}

[SOURce:]CURRent:OFFSet[:IMMediate]? [{MINimum|MAXimum}]

Parameter

Value PCR500LE: 0.35 to 3.85 (3.85 by default)
PCR1000LE: 0.7 to 7.70 (7.70 by default)
PCR2000LE: 1.4 to 15.40 (15.40 by default)
PCR3000LE: 2.1 to 23.10 (23.10 by default)
PCR4000LE: 2.80 to 30.80 (30.80 by default)
PCR6000LE: 4.2 to 46.20 (46.20 by default)
PCR9000LE: 6.3 to 69.30 (69.30 by default)
Unit A
Value PCR6000LE2:
  Single-phase output: 4.2 to 46.20 (46.20 by default)
  Single-phase three-wire output: 1.40 to 15.40 (15.40 by default)
  Three-phase output: 1.40 to 15.40 (15.40 by default)
PCR9000LE2:
  Single-phase output: 6.30 to 69.30 (69.30 by default)
  Single-phase three-wire output: 2.10 to 23.10 (23.10 by default)
  Three-phase output: 2.10 to 23.10 (23.10 by default)
PCR12000LE2:
  Single-phase output: 8.40 to 92.40 (92.40 by default)
  Single-phase three-wire output: 2.80 to 30.80 (30.80 by default)
  Three-phase output: 2.80 to 30.80 (30.80 by default)
PCR18000LE2:
  Single-phase output: 12.60 to 138.60 (138.60 by default)
  Single-phase three-wire output: 4.20 to 46.20 (46.20 by default)
  Three-phase output: 4.20 to 46.20 (46.20 by default)
PCR27000LE2:
  Single-phase output: 18.90 to 207.90 (207.90 by default)
  Single-phase three-wire output: 6.30 to 69.30 (69.30 by default)
  Three-phase output: 6.30 to 69.30 (69.30 by default)
Unit A
Value PCR500M: 0.1 to 4.2 (4.2 by defaul)
PCR1000M: 0.2 to 8.4 (8.4 by default)
PCR2000M: 0.4 to 16.8 (16.8 by default)
PCR4000M: 0.8 to 33.6 (33.6 by default)
Unit A

For the setting that is applied when *RST is sent, see this table

For the setting that is applied when *RST is sent, see this table

For the setting that is applied when *RST is sent, see this table

Response

Response

Returns the DC current upper limit in NR3 format in response to CURR:OFFS?.

In case of the single-phase three-wire output, CURR:OFFS? returns a comma-separated list of the DC current upper limit values <NR3> for U and V phases.

In case of the three-phase output, CURR:OFFS? returns a comma-separated list of the DC current upper limit values <NR3> for U, V, and W phases.

Command (function search)

Command (ABC search)

Command (Sub-system search)

Register

Appendix

Tutorial

AC power supply  PCR-M seriesAC Power Supply PCR-LE series
Communication Interface Manual

AC power supply  PCR-M seriesAC Power Supply PCR-LE2 series
Communication Interface Manual

AC power supply  PCR-M seriesAC Power Supply PCR-M series
Communication Interface Manual