CURR:PROT:STAT

Sets the PCR acts when the current limit is exceeded.

You cannot set the time (it is fixed to 3 seconds).

When you have specified the ON parameter (to select TRIP), use the CURR:PROT:TRIP:TIME command to set the time that must elapse after a limit has been exceeded before the protection functions are tripped.

Command

[SOURce:]CURRent:PROTection:STATe {ON|OFF|1|0}

[SOURce:]CURRent:PROTection:STATe?

Parameter

Value ON(1) TRIP (when an overload occurs for longer than the specified time, the output is turned off, and an alarm is generated; default).
  OFF(0) CC (when an overload occurs, the output is lowered so that the current limit is not exceeded). CC (when an overload occurs, the output is lowered so that the current limit is not exceeded).
When you have set the compensation function to the soft sensing function or the regulation adjustment function (SYST:CONF:SENS:MODE SENS2|RADJ), you cannot set this to OFF. If the EX05-PCR-LE is in use (optional) and the signal source is set to external signal source or internal signal source plus external signal source (FUNC:SOUR EXT|SUM), OFF cannot be selected.

For the setting that is applied when *RST is sent, see this table

For the setting that is applied when *RST is sent, see this table

For the setting that is applied when *RST is sent, see this table

Response

Response

Returns the PCR acts when the current limit is exceeded in NR1 format in response to CURR:PROT:STAT?.

Command (function search)

Command (ABC search)

Command (Sub-system search)

Register

Appendix

Tutorial

AC power supply  PCR-M seriesAC Power Supply PCR-LE series
Communication Interface Manual

AC power supply  PCR-M seriesAC Power Supply PCR-LE2 series
Communication Interface Manual

AC power supply  PCR-M seriesAC Power Supply PCR-M series
Communication Interface Manual