AC Power Supply PCR-LE series

AC Power Supply PCR-LE2 series

AC Power Supply PCR-M series

Commnunication Interface Mannual


 

CURR{1|2|3}:PEAK

Sets the output peak current limit of the positive electric potential of each phase.

This command is valid in single-phase three-wire output or three-phase output (optional).

Command

U phase

[SOURce:]CURRent1:PEAK[:UPPer][:IMMediate] {<numeric>|MINimum|MAXimum}

[SOURce:]CURRent1:PEAK[:UPPer][:IMMediate]? [{MINimum|MAXimum}]

V phase

[SOURce:]CURRent2:PEAK[:UPPer][:IMMediate] {<numeric>|MINimum|MAXimum}

[SOURce:]CURRent2:PEAK[:UPPer][:IMMediate]? [{MINimum|MAXimum}]

W phase (Three-phase output only)

[SOURce:]CURRent3:PEAK[:UPPer][:IMMediate] {<numeric>|MINimum|MAXimum}

[SOURce:]CURRent3:PEAK[:UPPer][:IMMediate]? [{MINimum|MAXimum}]

Parameter

Value PCR500LE: 0.5 to 22.0 (22.0 by default)
PCR1000LE: 1.0 to 44.0 (44.0 by default)
PCR2000LE: 2.0 to 88.0 (88.0 by default)
PCR3000LE: 3.0 to 132.0 (132.0 by default)
PCR4000LE: 4.0 to 176.0 (176.0 by default)
PCR6000LE: 6.0 to 264.0 (264.0 by default)
PCR9000LE: 9.0 to 396.0 (396.0 by default)
PCR6000LE2:
  Single-phase output: 6.0 to 264.0(264.0 by default)
  Single-phase three-wire output: 2.0 to 88.0 (88.0 by default)
  Three-phase output: 2.0 to 88.0 (88.0 by default)
PCR9000LE2:
  Single-phase output: 9.0 to 396.0 (396.0 by default)
  Single-phase three-wire output: 3.0 to 132.0 (132.0 by default)
  Three-phase output: 3.0 to 132.0 (132.0 by default)
PCR12000LE2:
  Single-phase output: 12.0 to 528.0 (528.0 by default)
  Single-phase three-wire output: 4.0 to 176.0 (176.0 by default)
  Three-phase output: 4.0 to 176.0 (176.0 by default)
PCR18000LE2:
  Single-phase output: 18.0 to 792.0 (792.0 by default)
  Single-phase three-wire output: 6.0 to 264.0 (264.0 by default)
  Three-phase output: 6.0 to 264.0 (264.0 by default)
PCR27000LE2:
  Single-phase output: 27.0 to 1188 (1188 by default)
  Single-phase three-wire output: 9.0 to 396.0 (396.0 by default)
  Three-phase output: 9.0 to 396.0 (396.0 by default)
Unit A

For the setting that is applied when *RST is sent, see this table

For the setting that is applied when *RST is sent, see this table

For the setting that is applied when *RST is sent, see this table

Response

Response

Returns the output peak current limit of the positive electric potential of U phase in NR3 format in response to CURR1:PEAK?.

Returns the output peak current limit of the positive electric potential of V phase in NR3 format in response to CURR2:PEAK?.

Returns the output peak current limit of the positive electric potential of W phase in NR3 format in response to CURR3:PEAK?.

Command (function search)

Command (ABC search)

Command (Sub-system search)

Register

Appendix

Tutorial

AC power supply  PCR-M seriesAC Power Supply PCR-LE series
Communication Interface Manual

AC power supply  PCR-M seriesAC Power Supply PCR-LE2 series
Communication Interface Manual

AC power supply  PCR-M seriesAC Power Supply PCR-M series
Communication Interface Manual