Tutorial
Output Phase Setting
The PCR-LE2 Series has three output methods: single-phase, single-phase three-wire, and three-phase.
If you select single-phase output, signals are output from the OUTPUT 1P2W terminal block.
If you select single-phase three-wire output or three-phase output, signals are output from the OUTPUT 3P4W (1P3W) terminal block. During single-phase three-wire output, current will not flow through the W terminal.
Sets the output mode. The output mode setting is valid when power cycling is not necessary.
:SYSTem:CONFigure:WIRing P1 'Set to single-phase output.
When you change the setting, some of the other settings are reset to their factory default values (reset condition).
If you switch between single-phase three-wire output and three-phase output, you must turn the PCR-LE2 series off and then back on.
If you change from single-phase three-wire output to single-phase output and then to three-phase output, you must turn the POWER switch off and then back on after you switch from single-phase output to three-phase output.
Likewise, if you change from three-phase output to single-phase output and then to single-phase three-wire output, you must turn the POWER switch off and then back on after you switch from single-phase output to single-phase three-wire output.
You cannot use commands to change the output mode if the change requires power cycling. In such a case, change it from front panel. You can query the output mode that the PCR-LE2 series can change to without power recycling.
:SYSTem:CONFigure:WIRing:CATalog? 'Queries the output mode that the PCR-LE2 series can change to without power recycling.