VOLT{1|2|3}
Sets the AC voltage of each phase.
This command is valid in single-phase three-wire output or three-phase output (PCR-LE optional).
This command is valid in AC mode (when the parameter to OUTP:COUP is AC).
If the EX05-PCR-LE is in use (optional) and the signal source is set to external signal source (FUNC:SOUR EXT), this command is invalid.
If the EX06-PCR-LE is in use (optional) and the AC voltage is being controlled with an external signal (VOLT:EXT:SOUR VOLT), this command is invalid.
Command
U phase
[SOURce:]VOLTage1[:LEVel][:IMMediate][:AMPLitude] {<numeric>|MINimum|MAXimum}
[SOURce:]VOLTage1[:LEVel][:IMMediate][:AMPLitude]? [{MINimum|MAXimum}]
V phase
[SOURce:]VOLTage2[:LEVel][:IMMediate][:AMPLitude] {<numeric>|MINimum|MAXimum}
[SOURce:]VOLTage2[:LEVel][:IMMediate][:AMPLitude]? [{MINimum|MAXimum}]
W phase (Three-phase output only)
[SOURce:]VOLTage3[:LEVel][:IMMediate][:AMPLitude] {<numeric>|MINimum|MAXimum}
[SOURce:]VOLTage3[:LEVel][:IMMediate][:AMPLitude]? [{MINimum|MAXimum}]
Parameter
Value | L range: 0 to 152.5 H range: 0 to 305.0 A SCPI error (-222, "Data out of range") occurs if outside the range. The default value is 0. |
Unit | V |
For the setting that is applied when *RST is sent, see this table
For the setting that is applied when *RST is sent, see this table
For the setting that is applied when *RST is sent, see this table
Response
Response
Returns the AC voltage setting of U phase in NR3 format in response to VOLT1?.
Returns the AC voltage setting of V phase in NR3 format in response to VOLT2?.
Returns the AC voltage setting of W phase in NR3 format in response to VOLT3?.