AC Power Supply PCR-LE series

AC Power Supply PCR-LE2 series

AC Power Supply PCR-M series

Commnunication Interface Mannual


 

Command (Function)

Sequence Operations

The second level nodes are SEQuence5 and PROGram. Regardless of which node you use, the PCR operates in the same way when it receives the commands.

-> Tutorial

 

Configuring sequences

PROG:EDIT Edits a sequence step (excluding the jump, impedance, and phase settings)
PROG:EDIT:JUMP Edits the jump settings of a sequence step
PROG:EDIT:OIMP:RAT Edits the output impedance settings of a sequence step
PROG:EDIT:PHAS:STAR Edits the starting phase angle settings and the phase chage setting of a sequence step
PROG:EDIT:PHAS:STOP Edits the ending phase angle settings of a sequence step
PROG:LOOP Sets the number of sequence repetitions
PROG:CLE Sets all the steps in the sequence to their default values
PROG:STEP:STAR Sets the sequence starting step number
PROG:STEP:END Sets the sequence ending step number
SYST:CONF:STAT:OUTP:POL Sets the status signal output polarity
SYST:CONF:TRIG:INP:POL Sets the trigger signal input polarity
SYST:CONF:TRIG:OUTP:POL Sets the trigger signal output polarity

Executing sequences

TRIG:SEQ5:SOUR
TRIG:PROG:SOUR
Sets the trigger source of the sequence 5 group
INIT:SEQ5 Starts the trigger function of the sequence 5 group
INIT:NAME Starts the trigger function of the specified sequence group
PROG:EXEC Queries the execution state of the sequence
PROG:STAT Changes the execution state of the sequence
TRIG:SEQ5
TRIG:PROG
Sequence 5 group software trigger
ABOR Aborts the trigger function

Sequence Operations
(Single-phase, three-wire output/ Three-phase output)

PROG:EDIT:PHAS:UOFF Sets the U phase offset of the sequence
PROG:EDIT:PHAS:UV Sets the U-V phase difference of a sequence step
PROG:EDIT:PHAS:UW Sets the U-W phase difference of a sequence step (3P05-PCR-LE only)
PROG:EDIT:VOLT{0|1|2|3} Sets the unbalanced AC voltage of a sequence step
PROG:EDIT:VOLT{0|1|2|3}:OFFS Sets the unbalanced DC voltage of a sequence step
PROG:EDIT:PHAS:RAMP Sets the phase change
SYST:CONF:PHAS:UOFF:INIT Clears the U phase offset setting

Advanced Operation
(Analog signal operation)

PROG:EXT:LOG Sets the logic of the sequence start/stop

>top

Command (function search)

Command (ABC search)

Command (Sub-system search)

Register

Appendix

Tutorial

AC power supply  PCR-M seriesAC Power Supply PCR-LE series
Communication Interface Manual

AC power supply  PCR-M seriesAC Power Supply PCR-LE2 series
Communication Interface Manual

AC power supply  PCR-M seriesAC Power Supply PCR-M series
Communication Interface Manual