AC Power Supply PCR-LE series

AC Power Supply PCR-LE2 series

AC Power Supply PCR-M series

Commnunication Interface Mannual


 

Command (Function)

Power Line Abnormality Simulations

The second level nodes are SEQuence4 and SIMulation. Regardless of which node you use, the PCR operates in the same way when it receives the commands.

Power line abnormality simulations are enabled in AC mode (OUTP:COUP AC).

-> Tutorial

 

Configuring power line abnormality simulations

SIM:T1:PHAS:STAT Selects the voltage regulation start (time or phase)
SIM:T1:TIME Sets the voltage regulation starting time
SIM:T1:PHAS Sets the voltage regulation starting phase
SIM:T2:TIME Sets slope time 1
SIM:T3:TIME Sets the voltage regulation time
SIM:T3:VOLT Sets the regulated voltage
SIM:T4:TIME Sets slope time 2
SIM:T5:CYCL:STAT Selects the duration that the voltage remains at the initial level (time or cycles)
SIM:T5:TIME Sets the return time
SIM:T5:CYCL Sets the return cycles
SIM:POL Sets the voltage regulation polarity
SIM:REP:COUN Sets the number of repetitions
SYST:CONF:STAT:OUTP:POL Sets the status signal output polarity

Executing power line abnormality simulations

SIM:STAT Executes and stops power line abnormality simulations
SIM:EXEC Queries the execution status of power line abnormality simulations
TRIG:SEQ4:SOUR
TRIG:SIM:SOUR
Sets the trigger source of the sequence 4 group
INIT:SEQ4 Starts the trigger function of the sequence 4 group
INIT:NAME Starts the trigger function of the specified sequence group
TRIG:SEQ4
TRIG:SIM
Sequence 4 group software trigger
ABOR Aborts the trigger function

>top

Command (function search)

Command (ABC search)

Command (Sub-system search)

Register

Appendix

Tutorial

AC power supply  PCR-M seriesAC Power Supply PCR-LE series
Communication Interface Manual

AC power supply  PCR-M seriesAC Power Supply PCR-LE2 series
Communication Interface Manual

AC power supply  PCR-M seriesAC Power Supply PCR-M series
Communication Interface Manual