CURR{1|2|3}
Sets the AC current upper limit of each phase.
This command is valid in single-phase three-wire output or three-phase output (optional).
This command is valid in AC mode (OUTP:COUP AC).
Command
U phase
[SOURce:]CURRent1[:LEVel][:IMMediate][:AMPLitude] {<numeric>|MINimum|MAXimum}
[SOURce:]CURRent1[:LEVel][:IMMediate][:AMPLitude]? [{MINimum|MAXimum}]
V phase
[SOURce:]CURRent2[:LEVel][:IMMediate][:AMPLitude] {<numeric>|MINimum|MAXimum}
[SOURce:]CURRent2[:LEVel][:IMMediate][:AMPLitude]? [{MINimum|MAXimum}]
W phase (Three-phase output only)
[SOURce:]CURRent3[:LEVel][:IMMediate][:AMPLitude] {<numeric>|MINimum|MAXimum}
[SOURce:]CURRent3[:LEVel][:IMMediate][:AMPLitude]? [{MINimum|MAXimum}]
Parameter
Value | PCR500LE: 0.5 to 5.5 (5.5 by default) PCR1000LE: 1.0 to 11.0 (11.0 by default) PCR2000LE: 2.0 to 22.0 (22.0 by default) PCR3000LE: 3.0 to 33.0 (33.0 by default) PCR4000LE: 4.0 to 44.0 (44.0 by default) PCR6000LE: 6.0 to 66.0 (66.0 by default) PCR9000LE: 9.0 to 99.0 (99.0 by default) |
PCR6000LE2: Single-phase output: 6.0 to 66.0 (66.0 by default) Single-phase three-wire output:2.0 to 22.0 (22.0 by default) Three-phase output:2.0 to 22.0 (22.0 by default) PCR9000LE2: Single-phase output: 9.0 to 99.0 (99.0 by default) Single-phase three-wire outputt:3.0 to 33.0 (33.0 by default) Three-phase output:3.0 to 33.0 (33.0 by default) PCR12000LE2: Single-phase output: 12.0 to 132.0 (132.0 by default) Single-phase three-wire outputt:4.0 to 44.0 (44.0 by default) Three-phase output:4.0 to 44.0 (44.0 by default) PCR18000LE2: Single-phase output: 18.0 to 198.0 (198.0 by default) Single-phase three-wire outputt:6.0 to 66.0 (66.0 by default) Three-phase output:6.0 to 66.0 (66.0 by default) PCR27000LE2: Single-phase output: 27.0 to 297.0 (297.0 by default) Single-phase three-wire output:9.0 to 99.0 (99.0 by default) Three-phase output:9.0 to 99.0 (99.0 by default) |
For the setting that is applied when *RST is sent, see this table
For the setting that is applied when *RST is sent, see this table
For the setting that is applied when *RST is sent, see this table
Response
Response
Returns the AC current upper limit of U phase in NR3 format in response to CURR1?.
Returns the AC current upper limit of V phase in NR3 format in response to CURR2?.
Returns the AC current upper limit of W phase in NR3 format in response to CURR3?.