AC Power Supply PCR-LE series

AC Power Supply PCR-LE2 series

AC Power Supply PCR-M series

Commnunication Interface Mannual


 

CURR{1|2|3}

Sets the AC current upper limit of each phase.

This command is valid in single-phase three-wire output or three-phase output (optional).

This command is valid in AC mode (OUTP:COUP AC).

Command

U phase

[SOURce:]CURRent1[:LEVel][:IMMediate][:AMPLitude] {<numeric>|MINimum|MAXimum}

[SOURce:]CURRent1[:LEVel][:IMMediate][:AMPLitude]? [{MINimum|MAXimum}]

V phase

[SOURce:]CURRent2[:LEVel][:IMMediate][:AMPLitude] {<numeric>|MINimum|MAXimum}

[SOURce:]CURRent2[:LEVel][:IMMediate][:AMPLitude]? [{MINimum|MAXimum}]

W phase (Three-phase output only)

[SOURce:]CURRent3[:LEVel][:IMMediate][:AMPLitude] {<numeric>|MINimum|MAXimum}

[SOURce:]CURRent3[:LEVel][:IMMediate][:AMPLitude]? [{MINimum|MAXimum}]

Parameter

Value PCR500LE: 0.5 to 5.5 (5.5 by default)
PCR1000LE: 1.0 to 11.0 (11.0 by default)
PCR2000LE: 2.0 to 22.0 (22.0 by default)
PCR3000LE: 3.0 to 33.0 (33.0 by default)
PCR4000LE: 4.0 to 44.0 (44.0 by default)
PCR6000LE: 6.0 to 66.0 (66.0 by default)
PCR9000LE: 9.0 to 99.0 (99.0 by default)
PCR6000LE2:
  Single-phase output: 6.0 to 66.0 (66.0 by default)
  Single-phase three-wire output:2.0 to 22.0 (22.0 by default)
  Three-phase output:2.0 to 22.0 (22.0 by default)
PCR9000LE2:
  Single-phase output: 9.0 to 99.0 (99.0 by default)
  Single-phase three-wire outputt:3.0 to 33.0 (33.0 by default)
  Three-phase output:3.0 to 33.0 (33.0 by default)
PCR12000LE2:
  Single-phase output: 12.0 to 132.0 (132.0 by default)
  Single-phase three-wire outputt:4.0 to 44.0 (44.0 by default)
  Three-phase output:4.0 to 44.0 (44.0 by default)
PCR18000LE2:
  Single-phase output: 18.0 to 198.0 (198.0 by default)
  Single-phase three-wire outputt:6.0 to 66.0 (66.0 by default)
  Three-phase output:6.0 to 66.0 (66.0 by default)
PCR27000LE2:
  Single-phase output: 27.0 to 297.0 (297.0 by default)
  Single-phase three-wire output:9.0 to 99.0 (99.0 by default)
  Three-phase output:9.0 to 99.0 (99.0 by default)

For the setting that is applied when *RST is sent, see this table

For the setting that is applied when *RST is sent, see this table

For the setting that is applied when *RST is sent, see this table

Response

Response

Returns the AC current upper limit of U phase in NR3 format in response to CURR1?.

Returns the AC current upper limit of V phase in NR3 format in response to CURR2?.

Returns the AC current upper limit of W phase in NR3 format in response to CURR3?.

Command (function search)

Command (ABC search)

Command (Sub-system search)

Register

Appendix

Tutorial

AC power supply  PCR-M seriesAC Power Supply PCR-LE series
Communication Interface Manual

AC power supply  PCR-M seriesAC Power Supply PCR-LE2 series
Communication Interface Manual

AC power supply  PCR-M seriesAC Power Supply PCR-M series
Communication Interface Manual