AC Power Supply PCR-LE series

AC Power Supply PCR-LE2 series

AC Power Supply PCR-M series

Commnunication Interface Mannual


 

VOLT:OFFS:PROT:LEV:LOW (PCR-LE/ PCR-LE2 only)

Sets the UVP value used to judge averaged voltage measurements.

This command is valid in DC mode and AC+DC mode (OUTP:COUP DC|ACDC).

During single-phase, three-wire output (PCR-LE optional), set the voltage using phase voltage of the U phase.

Command

[SOURce:]VOLTage:OFFSet:PROTection:LEVel:LOWer {<numeric>|MINimum|MAXimum}

[SOURce:]VOLTage:OFFSet:PROTection:LEVel:LOWer? [{MINimum|MAXimum}]

Parameter

Value -474.1 to 474.1 (-474.1 by default)
An SCPI error (-222, "Data out of range") occurs if the specified value is outside the range.
Unit V

For the setting that is applied when *RST is sent, see this table

For the setting that is applied when *RST is sent, see this table

For the setting that is applied when *RST is sent, see this table

Response

Response

Returns the UVP value in NR3 format in response to VOLT:OFFS:PROT:LEV:LOW?.