AC Power Supply PCR-LE series

AC Power Supply PCR-LE2 series

AC Power Supply PCR-M series

Commnunication Interface Mannual


 

CURR{1|2|3}:PEAK:LOW

Sets the output peak current limit of the negative electric potential of each phase.

This command is valid in single-phase three-wire output or three-phase output (optional).

Command

U phase

[SOURce:]CURRent1:PEAK:LOWer[:IMMediate] {<numeric>|MINimum|MAXimum}

[SOURce:]CURRent1:PEAK:LOWer[:IMMediate]? [{MINimum|MAXimum}]

V phase

[SOURce:]CURRent2:PEAK:LOWer[:IMMediate] {<numeric>|MINimum|MAXimum}

[SOURce:]CURRent2:PEAK:LOWer[:IMMediate]? [{MINimum|MAXimum}]

W phase (Three-phase output only)

[SOURce:]CURRent3:PEAK:LOWer[:IMMediate] {<numeric>|MINimum|MAXimum}

[SOURce:]CURRent3:PEAK:LOWer[:IMMediate]? [{MINimum|MAXimum}]

Parameter

Value PCR500LE: -0.5 to -22.0 (-22.0 by default)
PCR1000LE: -1.0 to -44.0 (-44.0 by default)
PCR2000LE: -2.0 to -88.0 (-88.0 by default)
PCR3000LE: -3.0 to -132.0 (-132.0 by default)
PCR4000LE: -4.0 to -176.0 (-176.0 by default)
PCR6000LE: -6.0 to -264.0 (-264.0 by default)
PCR9000LE: -9.0 to -396.0 (-396.0 by default)
PCR6000LE2:
  Single-phase output: -6.0 to -264.0(-264.0 by default)
  Single-phase three-wire output: -2.0 to -88.0 (-88.0 by default)
  Three-phase output: -2.0 to -88.0 (-88.0 by default)
PCR9000LE2:
  Single-phase output: -9.0 to -396.0 (-396.0 by default)
  Single-phase three-wire outputt: -3.0 to -132.0 (-132 by default)
  Three-phase output: -3.0 to -132.0 (-132.0 by default)
PCR12000LE2:
  Single-phase output: -12.0 to -528.0 (-528.0 by default)
  Single-phase three-wire output: -4.0 to -176.0 (-176.0 by default)
  Three-phase output: -4.0 to -176.0 (-176.0 by default)
PCR18000LE2:
  Single-phase output: -18.0 to -792.0 (-792.0 by default)
  Single-phase three-wire output: -6.0 to -264.0 (-264.0 by default)
  Three-phase output: -6.0 to -264.0 (-264.0 by default)
PCR27000LE2:
  Single-phase output: -27.0 to -1188 (-1188 by default)
  Single-phase three-wire output: -9.0 to -396.0 (-396.0 by default)
  Three-phase output: -9.0 to -396.0 (-396.0 by default)
Unit A

For the setting that is applied when *RST is sent, see this table

For the setting that is applied when *RST is sent, see this table

For the setting that is applied when *RST is sent, see this table

Response

Response

Returns the output peak current limit of the negative electric potential of U phase in NR3 format in response to CURR1:PEAK:LOW?.

Returns the output peak current limit of the negative electric potential of V phase in NR3 format in response to CURR2:PEAK:LOW?.

Returns the output peak current limit of the negative electric potential of W phase in NR3 format in response to CURR3:PEAK:LOW?.

Command (function search)

Command (ABC search)

Command (Sub-system search)

Register

Appendix

Tutorial