FREQ:SYNC

Sets the synchronization function.

This is valid in AC mode and AC+DC mode (OUTP:COUP AC|ACDC).

If the EX05-PCR-LE is in use (optional) and the signal source is set to external signal source (FUNC:SOUR EXT), this command is invalid.

Use FREQ:SYNC:PHASE:DEL to set the synchronization delay phase angle.

Command

[SOURce:]FREQuency:SYNChronous[:STATe] {ON|OFF|1|0}

[SOURce:]FREQuency:SYNChronous[:STATe]?

Parameter

Value ON(1) The synchronization function is enabled.
  OFF(0) The synchronization function is disabled (default).

For the setting that is applied when *RST is sent, see this table

For the setting that is applied when *RST is sent, see this table

For the setting that is applied when *RST is sent, see this table

Response

Response

Returns the synchronization function in NR1 format in response to FREQ:SYNC?.