AC Power Supply PCR-LE series

AC Power Supply PCR-LE2 series

AC Power Supply PCR-M series

Commnunication Interface Mannual


 

VOLT:OFFS:LIM

Sets the upper limit value of DC voltage.

This command is valid in DC mode and AC+DC mode (OUTP:COUP DC|ACDC).

If the EX05-PCR-LE is in use (PCR-LE/PCR-LE2 optional) and the signal source is set to external signal source (FUNC:SOUR EXT), this command is invalid.

During single-phase, three-wire output (PCR-LE optional), set the voltage using phase voltage of the U phase.

Command

[SOURce:]VOLTage:OFFSet:LIMit[:UPPer] {<numeric>|MINimum|MAXimum}

[SOURce:]VOLTage:OFFSet:LIMit[:UPPer]? [{MINimum|MAXimum}]

Parameter

Value

PCR-M:
DC mode, 135V range: -194.0 to 388.0 (388.0 by default)
DC mode, 270V range: -388.0 to 388.0 (388.0 by default)
 
PCR-LE/PCR-LE2: -431.0 to 431.0 (431.0 by default)
 
A SCPI error (-222, "Data out of range") occurs if outside the range.

Unit V

For the setting that is applied when *RST is sent, see this table

For the setting that is applied when *RST is sent, see this table

For the setting that is applied when *RST is sent, see this table

Response

Response

Returns the upper limit setting of DC voltage in NR3 format in response to VOLT:OFFS:LIM?.