AC Power Supply PCR-LE series

AC Power Supply PCR-LE2 series

AC Power Supply PCR-M series

Commnunication Interface Mannual


 

Command (Function)

Output On/Off Phase Control

The PCR-M only has output on phase control. It does not have output off phase control.

The second level nodes are SEQuence2 and SYNChronize. Regardless of which node you use, the PCR operates in the same way when it receives the commands.

The PCR-M's sequence 2 group phase is controlled by the output being turned on, not by software triggers. To stop phase control, send the TRIG:SEQ2:SOUR IMM or TRIG:SYNC:SOUR IMM command.

-> Tutorial

 

TRIG:SEQ2:SOUR
TRIG:SYNC:SOUR
Sets the output on phase control
TRIG:SEQ2:PHAS
TRIG:SYNC:PHAS
Sets the phase angle of output on phase control
ABOR Aborts the trigger function

>top

Command (function search)

Command (ABC search)

Command (Sub-system search)

Register

Appendix

Tutorial