VOLT{1|2|3}:OFFS (PCR-LE/ PCR-LE2 only)

Sets the DC voltage of each phase.

This command is valid in DC mode or AC+DC mode (when the parameter to OUTP:COUP is DC|ACDC).

This command is valid in two-phase output(SYST:CONF:TPH:MODE ON) or three-phase output (optional).

If the EX05-PCR-LE is in use (optional) and the signal source is set to external signal source (FUNC:SOUR EXT), this command is invalid.

Command

U phase

[SOURce:]VOLTage1:OFFSet[:LEVel][:IMMediate][:AMPLitude] {<numeric>|MINimum|MAXimum}

[SOURce:]VOLTage1:OFFSet[:LEVel][:IMMediate][:AMPLitude]? [{MINimum|MAXimum}]

V phase

[SOURce:]VOLTage2:OFFSet[:LEVel][:IMMediate][:AMPLitude] {<numeric>|MINimum|MAXimum}

[SOURce:]VOLTage2:OFFSet[:LEVel][:IMMediate][:AMPLitude]? [{MINimum|MAXimum}]

W phase (Three-phase output only)

[SOURce:]VOLTage3:OFFSet[:LEVel][:IMMediate][:AMPLitude] {<numeric>|MINimum|MAXimum}

[SOURce:]VOLTage3:OFFSet[:LEVel][:IMMediate][:AMPLitude]? [{MINimum|MAXimum}]

Parameter

Value DC mode, L range: -215.5 to 215.5
DC mode, H range: -431.0 to 431.0
AC+DC mode, L range: This can only be set when the AC and DC voltages are within the settable ranges defined by the voltage limits and the AC+DC waveform peak is between -215.5 V and 215.5 V.
AC+DC mode, H range: This can only be set when the AC and DC voltages are within the settable ranges defined by the voltage limits and the AC+DC waveform peak is between -431 V and 431 V.

A SCPI error (-222, "Data out of range") occurs if outside the range.
The default value is 0.
Unit V

For the setting that is applied when *RST is sent, see this table

For the setting that is applied when *RST is sent, see this table

For the setting that is applied when *RST is sent, see this table

Response

Response

Returns the DC voltage setting of U phase in NR3 format in response to VOLT1:OFFS?.

Returns the DC voltage setting of V phase in NR3 format in response to VOLT2:OFFS?.

Returns the DC voltage setting of W phase in NR3 format in response to VOLT3:OFFS?.

Command (function search)

Command (ABC search)

Command (Sub-system search)

Register

Appendix

Tutorial

AC power supply  PCR-M seriesAC Power Supply PCR-LE series
Communication Interface Manual

AC power supply  PCR-M seriesAC Power Supply PCR-LE2 series
Communication Interface Manual

AC power supply  PCR-M seriesAC Power Supply PCR-M series
Communication Interface Manual