AC Power Supply PCR-LE series

AC Power Supply PCR-LE2 series

AC Power Supply PCR-M series

Commnunication Interface Mannual


 

VOLT{1|2|3}:OFFS:TRIG (PCR-LE/ PCR-LE2 only)

Sets the DC voltage of each phase that is applied when INIT/INIT:NAME TRAN and a software trigger are sent.

This command is valid in DC mode or AC+DC mode (OUTP:COUP DC|ACDC).

This command is valid in two-phase output(SYST:CONF:TPH:MODE ON) or three-phase output (optional).

Command

U phase

[SOURce:]VOLTage1:OFFSet[:LEVel]:TRIGgered[:AMPLitude] {<numeric>|MINimum|MAXimum}

[SOURce:]VOLTage1:OFFSet[:LEVel]:TRIGgered[:AMPLitude]? [{MINimum|MAXimum}]

V phase

[SOURce:]VOLTage2:OFFSet[:LEVel]:TRIGgered[:AMPLitude] {<numeric>|MINimum|MAXimum}

[SOURce:]VOLTage2:OFFSet[:LEVel]:TRIGgered[:AMPLitude]? [{MINimum|MAXimum}]

W phase (Three-phase output only)

[SOURce:]VOLTage3:OFFSet[:LEVel]:TRIGgered[:AMPLitude] {<numeric>|MINimum|MAXimum}

[SOURce:]VOLTage3:OFFSet[:LEVel]:TRIGgered[:AMPLitude]? [{MINimum|MAXimum}]

Parameter

Value DC mode, L range: -215.5 to 215.5
DC mode, H range: -431.0 to 431.0
AC+DC mode, L range: This can only be set when the AC and DC voltages are within the settable ranges defined by the voltage limits and the AC+DC waveform peak is between -215.5 V and 215.5 V.
AC+DC mode, H range: This can only be set when the AC and DC voltages are within the settable ranges defined by the voltage limits and the AC+DC waveform peak is between -431 V and 431 V.

A SCPI error (-222, "Data out of range") occurs if outside the range.
The default value is 0.
Unit V

For the setting that is applied when *RST is sent, see this table

For the setting that is applied when *RST is sent, see this table

For the setting that is applied when *RST is sent, see this table

Response

Response

Returns the  target value of U phase to which the DC voltage is to change using a trigger in NR3 format in response to VOLT1:OFFS:TRIG?.

Returns the  target value of V phase to which the DC voltage is to change using a trigger in NR3 format in response to VOLT2OFFS::TRIG?.

Returns the  target value of W phase to which the DC voltage is to change using a trigger in NR3 format in response to VOLT3:OFFS:TRIG?.

Command (function search)

Command (ABC search)

Command (Sub-system search)

Register

Appendix

Tutorial

AC power supply  PCR-M seriesAC Power Supply PCR-LE series
Communication Interface Manual

AC power supply  PCR-M seriesAC Power Supply PCR-LE2 series
Communication Interface Manual

AC power supply  PCR-M seriesAC Power Supply PCR-M series
Communication Interface Manual