PROG:EDIT:PHAS:STAR

Configures the starting phase angle settings and the phase change setting of a sequence step.

Command

PROGram:EDIT:PHASe:STARt <step_NR1>,<enable_bool>[,<phase_numeric>[,<phase_change_bool>]]

PROGra:EDIT:PHASe:STARt? <step_NR1>

Parameter <step_NR1>

Value 0 to 599 Number of the step that you want to configure

Parameter <enable_bool> {ON|OFF|1|0}

Value ON(1) Enables phase control
OFF(0) Disables phase control

Parameter <phase_numeric> {numeric|MAXimum|MINimum}

Value 0 to 359 Starting phase angle
Unit DEG

Parameter <phase_change_bool> {ON|OFF|1|0}

Value ON(1) Enables phase change
OFF(0) Disables phase change

Response

Returns the starting phase angle settings and the phase change setting of the specified step in the following order in response to PROG:EDIT:PHAS:STAR? <step_NR1>.

Whether the phase is controlled <NR1>,starting phase angle <NR3>, phase change setting<NR1>