AC Power Supply PCR-LE series

AC Power Supply PCR-LE2 series

AC Power Supply PCR-M series

Commnunication Interface Mannual


 

TRIG:SEQ5:SOUR/ TRIG:PROG:SOUR

Sets the condition (trigger source) that determines when the sequence 5 group actually executes a sequence operation after the PCR receives the INIT:SEQ5 PROG or INIT:NAME PROG command.

Command

TRIGger:SEQuence5:SOURce {IMMediate|BUS}

TRIGger:SEQuence5:SOURce?

TRIGger:PROGram:SOURce {IMMediate|BUS}

TRIGger:PROGram:SOURce?

Parameter

Value IMM The sequence starts immediately (default).
  BUS The PCR waits for a software trigger (a *TRG, TRIG:SEQ3, or IEEE 488.1 get (Group Execute Trigger) command), and then the sequence starts.

For the setting that is applied when *RST is sent, see this table

For the setting that is applied when *RST is sent, see this table

For the setting that is applied when *RST is sent, see this table

Response

Response

Returns the sequence 5 group's trigger source in CHAR format in response to TRIG:SEQ5:SOUR? or TRIG:PROG:SOUR?.

Command (function search)

Command (ABC search)

Command (Sub-system search)

Register

Appendix

Tutorial

AC power supply  PCR-M seriesAC Power Supply PCR-LE series
Communication Interface Manual

AC power supply  PCR-M seriesAC Power Supply PCR-LE2 series
Communication Interface Manual

AC power supply  PCR-M seriesAC Power Supply PCR-M series
Communication Interface Manual