AC Power Supply PCR-LE series

AC Power Supply PCR-LE2 series

AC Power Supply PCR-M series

Commnunication Interface Mannual


 

PROG:EDIT:PHAS:STOP

Configures the ending phase angle settings of a sequence step.

Command

PROGram:EDIT:PHASe:STOP <step_NR1>,<enable_bool>,[<phase_numeric>]

PROGram:EDIT:PHASe:STOP? <step_NR1>

Parameter <step_NR1>

Value 0 to 599 Number of the step that you want to configure

Parameter <enable_bool> {ON|OFF|1|0}

Value ON(1) Enables phase control
OFF(0) Disables phase control

Parameter <phase_numeric> {numeric|MAXimum|MINimum}

Value 0 to 359 Ending phase angle
Unit DEG

Response

Returns the ending phase angle settings of the specified step in the following order in response to PROG:EDIT:PHAS:STOP? <step_NR1>.

Whether the phase is controlled <NR1>,ending phase angle <NR3>

Command (function search)

Command (ABC search)

Command (Sub-system search)

Register

Appendix

Tutorial

AC power supply  PCR-M seriesAC Power Supply PCR-LE series
Communication Interface Manual

AC power supply  PCR-M seriesAC Power Supply PCR-LE2 series
Communication Interface Manual

AC power supply  PCR-M seriesAC Power Supply PCR-M series
Communication Interface Manual