AC Power Supply PCR-LE series

AC Power Supply PCR-LE2 series

AC Power Supply PCR-M series

Commnunication Interface Mannual


 

PROG:EDIT:PHAS:UW

Configures the U-W phase difference settings of a sequence step.

This command is valid in three-phase output (PCR-LE optional).

Command

PROGram:EDIT:PHASe:UW <step_NR1>,<enable_bool>,[<phase_numeric>]

PROGram:EDIT:PHASe:UW? <step_NR1>

Parameter <step_NR1>

Value 0 to 599 Number of the step that you want to configure

Parameter <enable_bool> {ON|OFF|1|0}

Value ON(1) Enables U-W phase difference control
OFF(0) Disables U-W phase difference control

Parameter <phase_numeric> {numeric|MAXimum|MINimum}

Value 0 to 359 U-W phase difference angle
Unit DEG

Response

Returns the U-W phase difference settings of the specified step in the following order in response to PROG:EDIT:PHAS:UW? <step_NR1>.

Whether the U-W phase difference is controlled <NR1>,U-W phase difference angle <NR3>