PROG:EDIT:VOLT:OFFS (PCR-LE/ PCR-LE2 only)

Configures the unbalanced DC voltage settings of a sequence step.

This command is valid in two-phase output or three-phase output (optional).

Command

All phases

PROGram:EDIT:VOLTage[0]:OFFSet <step_NR1>,<volt_numeric>

PROGram:EDIT:VOLTage[0]:OFFSet? <step_NR1>

U phase

PROGram:EDIT:VOLTage1:OFFSet <step_NR1>,<volt_numeric>

PROGram:EDIT:VOLTage1:OFFSet? <step_NR1>

V phase

PROGram:EDIT:VOLTage2:OFFSet <step_NR1>,<volt_numeric>

PROGram:EDIT:VOLTage2:OFFSet? <step_NR1>

W phase (Three-phase output only)

PROGram:EDIT:VOLTage3:OFFSet <step_NR1>,<volt_numeric>

PROGram:EDIT:VOLTage3:OFFSet? <step_NR1>

Parameter <step_NR1>

Value 0 to 599 Number of the step that you want to configure

Parameter <volt_numeric> {numeric|MAXimum|MINimum}

Value 0 to 305 Unbalanced voltage
Unit V

Response

In case of the two-phase output, PROG:EDIT:VOLT:OFFS? <step_NR1> returns a comma-separated list of the DC voltage <NR3> of the specified step for U and V phases.

In case of the three-phase output, PROG:EDIT:VOLT:OFFS? <step_NR1> returns a comma-separated list of the DC voltage <NR3> of the specified step for U, V, and W phases.

Returns the DC voltage in NR3 format of U phase of the specified step in response to PROG:EDIT:VOLT1:OFFS? <step_NR1>.

Returns the DC voltage in NR3 format of V phase of the specified step in response to PROG:EDIT:VOLT2:OFFS? <step_NR1>.

Returns the DC voltage in NR3 format of W phase of the specified step in response to PROG:EDIT:VOLT3:OFFS? <step_NR1>.

Command (function search)

Command (ABC search)

Command (Sub-system search)

Register

Appendix

Tutorial

AC power supply  PCR-M seriesAC Power Supply PCR-LE series
Communication Interface Manual

AC power supply  PCR-M seriesAC Power Supply PCR-LE2 series
Communication Interface Manual

AC power supply  PCR-M seriesAC Power Supply PCR-M series
Communication Interface Manual