SIM:T1:TIME

Sets the voltage regulation starting time of power line abnormality simulations.

This command is valid when voltage regulations are configured to be set by time (SIM:T1:PHAS:STAT OFF).

Command

SIMulation:T1:TIME[:LEVel] {<numeric>|MINimum|MAXimum}

SIMulation:T1:TIME[:LEVel]? [{MINimum|MAXimum}]

Parameter

Value 0.0 to 999.9m (100m by default)
Unit S

For the setting that is applied when *RST is sent, see this table

For the setting that is applied when *RST is sent, see this table

For the setting that is applied when *RST is sent, see this table

Response

Response

Returns the voltage regulation starting time in NR3 format in response to SIM:T1:TIME?.