AC Power Supply PCR-LE series

AC Power Supply PCR-LE2 series

AC Power Supply PCR-M series

Commnunication Interface Mannual


 

TRIG:SEQ4:SOUR/ TRIG:SIM:SOUR

Sets the condition (trigger source) that determines when the sequence 4 group actually executes a sequence operation after the PCR receives the INIT:SEQ4 SIM or INIT:NAME SIM command.

Command

TRIGger:SEQuence4:SOURce {IMMediate|BUS}

TRIGger:SEQuence4:SOURce?

TRIGger:SIMulation:SOURce {IMMediate|BUS}

TRIGger:SIMulation:SOURce?

Parameter

Value IMM The sequence operation starts immediately (default).
  BUS The PCR waits for a software trigger (a *TRG, TRIG:SEQ2, or IEEE 488.1 get (Group Execute Trigger) command), and then the sequence operation starts.

For the setting that is applied when *RST is sent, see this table

For the setting that is applied when *RST is sent, see this table

For the setting that is applied when *RST is sent, see this table

Response

Response

Returns the sequence 4 group's trigger source in CHAR format in response to TRIG:SEQ4:SOUR? or TRIG:SIM:SOUR?.