SYST:CONF:POW:EXP

Sets the anticipated maximum power (power-saving function).

This command is not valid on the PCR500LE and PCR1000LE.

This command is valid when all power units are operating normally.

Single-phase three-wire output or Three-phase output (optional): Sets the AC current upper limit of all phases at once. If the connected PCR-LEPCR-LE2s are not of the same model, set the limit of each phase using SYST:CONF:POW{1|2|3}:EXP.

This command is valid during single-phase output.

Turn the POWER switch off and on to enable the setting.

Master-slave parallel operation (option) is valid only when the connected PCR-LE Series are of the same model.

Command

SYSTem:CONFigure:POWer[0]:EXPected[:MAXimum] {<numeric>|MINimum|MAXimum}

SYSTem:CONFigure:POWer[0]:EXPected[:MAXimum]? [{MINimum|MAXimum}]

Parameter

Value PCR2000LE: 1000, 2000 (2000 by default)
PCR3000LE: 1000, 2000, 3000 (3000 by default)
PCR4000LE: 1000, 2000, 3000, 4000 (4000 by default)
PCR6000LE: 1000, 2000, 3000, 4000, 5000、6000 (6000 by default)
PCR9000LE: 1000, 2000, 3000, 4000, 5000、6000、7000、8000、9000 (9000 by default)
The setting range during master-slave parallel operation is “1000VA x the number of parallel units” to “rated output capacity x the number of parallel units.” The resolution is 1000VA x the number of parallel units.
PCR6000LE2: 3000, 6000 (3000 by default)
PCR9000LE2: 3000, 6000, 9000 (9000 by default)
PCR12000LE2: 3000, 6000, 9000 12000 (12000 by default)
PCR18000LE2: 3000, 6000, 9000 12000, 15000, 18000 (18000 by default)
PCR27000LE2: 3000, 6000, 9000, 12000, 15000, 18000, 21000, 24000, 27000 (27000 by default)
Unit VA

Response

Returns the maximum anticipated power in NR3 format in response to SYST:CONF:POW:EXP?.

In case of the single-phase three-wire output, SYST:CONF:POW:EXP? returns a comma-separated list of the maximum anticipated power <NR3> for U and V phases.

In case of the three-phase output, SYST:CONF:POW:EXP? returns a comma-separated list of the maximum anticipated power <NR3> for U, V, and W phases.

Command (function search)

Command (ABC search)

Command (Sub-system search)

Register

Appendix

Tutorial

AC power supply  PCR-M seriesAC Power Supply PCR-LE series
Communication Interface Manual

AC power supply  PCR-M seriesAC Power Supply PCR-LE2 series
Communication Interface Manual

AC power supply  PCR-M seriesAC Power Supply PCR-M series
Communication Interface Manual