SYST:CONF:POW:EXP
Sets the anticipated maximum power (power-saving function).
This command is not valid on the PCR500LE and PCR1000LE.
This command is valid when all power units are operating normally.
Single-phase three-wire output or Three-phase output (optional): Sets the AC current upper limit of all phases at once. If the connected PCR-LEPCR-LE2s are not of the same model, set the limit of each phase using SYST:CONF:POW{1|2|3}:EXP.
This command is valid during single-phase output.
Turn the POWER switch off and on to enable the setting.
Master-slave parallel operation (option) is valid only when the connected PCR-LE Series are of the same model.
Command
SYSTem:CONFigure:POWer[0]:EXPected[:MAXimum] {<numeric>|MINimum|MAXimum}
SYSTem:CONFigure:POWer[0]:EXPected[:MAXimum]? [{MINimum|MAXimum}]
Parameter
Value | PCR2000LE: 1000, 2000 (2000 by default) PCR3000LE: 1000, 2000, 3000 (3000 by default) PCR4000LE: 1000, 2000, 3000, 4000 (4000 by default) PCR6000LE: 1000, 2000, 3000, 4000, 5000、6000 (6000 by default) PCR9000LE: 1000, 2000, 3000, 4000, 5000、6000、7000、8000、9000 (9000 by default) The setting range during master-slave parallel operation is “1000VA x the number of parallel units” to “rated output capacity x the number of parallel units.” The resolution is 1000VA x the number of parallel units. |
PCR6000LE2: 3000, 6000 (3000 by default)
PCR9000LE2: 3000, 6000, 9000 (9000 by default) PCR12000LE2: 3000, 6000, 9000 12000 (12000 by default) PCR18000LE2: 3000, 6000, 9000 12000, 15000, 18000 (18000 by default) PCR27000LE2: 3000, 6000, 9000, 12000, 15000, 18000, 21000, 24000, 27000 (27000 by default) |
Unit | VA |
Response
Returns the maximum anticipated power in NR3 format in response to SYST:CONF:POW:EXP?.
In case of the single-phase three-wire output, SYST:CONF:POW:EXP? returns a comma-separated list of the maximum anticipated power <NR3> for U and V phases.
In case of the three-phase output, SYST:CONF:POW:EXP? returns a comma-separated list of the maximum anticipated power <NR3> for U, V, and W phases.