AC Power Supply PCR-LE series

AC Power Supply PCR-LE2 series

AC Power Supply PCR-M series

Commnunication Interface Mannual


 

SYST:CONF:POW{1|2|3}:EXP

Sets the anticipated maximum power (power-saving function) of each phase.

This command is valid in single-phase three-wire output or three-phase output (optional).

Turn the POWER switch off and on to enable the setting.

Master-slave parallel operation (option) is valid only when the connected PCR-LE Series are of the same model.

Command

Setting of U phase

SYSTem:CONFigure:POWer1:EXPected[:MAXimum] {<numeric>|MINimum|MAXimum}

SYSTem:CONFigure:POWer1:EXPected[:MAXimum]? [{MINimum|MAXimum}]

Setting of V phase

SYSTem:CONFigure:POWer2:EXPected[:MAXimum] {<numeric>|MINimum|MAXimum}

SYSTem:CONFigure:POWer2:EXPected[:MAXimum]? [{MINimum|MAXimum}]

Setting of W phase (Three-phase output only)

SYSTem:CONFigure:POWer3:EXPected[:MAXimum] {<numeric>|MINimum|MAXimum}

SYSTem:CONFigure:POWer3:EXPected[:MAXimum]? [{MINimum|MAXimum}]

Parameter

Value PCR2000LE: 1000, 2000 (2000 by default)
PCR3000LE: 1000, 2000, 3000 (3000 by default)
PCR4000LE: 1000, 2000, 3000, 4000 (4000 by default)
PCR6000LE: 1000, 2000, 3000, 4000, 5000, 6000 (6000 by default)
PCR9000LE: 1000, 2000, 3000, 4000, 5000, 6000, 7000, 8000, 9000 (9000 by default)
The setting range during master-slave parallel operation is “1000VA x the number of parallel units” to “rated output capacity x the number of parallel units.” The resolution is 1000VA x the number of parallel units.
PCR6000LE2: 1000, 2000 (2000 by default)
PCR9000LE2: 1000, 2000, 3000 (3000 by default)
PCR12000LE2: 1000, 2000, 3000, 4000 (4000 by default)
PCR18000LE2: 1000, 2000, 3000, 4000, 5000, 6000 (6000 by default)
PCR27000LE2: 1000, 2000, 3000, 4000, 5000, 6000, 7000, 8000, 9000 (9000 by default)
Unit VA

Response

Returns the maximum anticipated power of U phase in NR3 format in response to SYST:CONF:POW1:EXP?.

Returns the maximum anticipated power of V phase in NR3 format in response to SYST:CONF:POW2:EXP?.

Returns the maximum anticipated power of W phase in NR3 format in response to SYST:CONF:POW3:EXP?.

Command (function search)

Command (ABC search)

Command (Sub-system search)

Register

Appendix

Tutorial

AC power supply  PCR-M seriesAC Power Supply PCR-LE series
Communication Interface Manual

AC power supply  PCR-M seriesAC Power Supply PCR-LE2 series
Communication Interface Manual

AC power supply  PCR-M seriesAC Power Supply PCR-M series
Communication Interface Manual