OUTP:PHAS:OFF
Sets whether output off phase control is used.
This command is valid in AC mode and AC+DC mode (OUTP:COUP AC|ACDC).
If the EX05-PCR-LE is in use (optional) and the signal source is set to external signal source (FUNC:SOUR EXT), this command is invalid.
Use OUTP:PHAS:OFF:LEV to set the output off phase angle.
Command
OUTPut:PHASe:OFF[:STATe] {ON|OFF|1|0}
OUTPut:PHASe:OFF[:STATe]?
Parameter
Value | ON(1) | The output off phase is controlled. |
OFF(0) | The output off phase is not controlled (default). |
For the setting that is applied when *RST is sent, see this table
For the setting that is applied when *RST is sent, see this table
For the setting that is applied when *RST is sent, see this table
Response
Response
Returns whether the output off phase control is used in NR1 format in response to OUTP:PHAS:OFF?.