AC Power Supply PCR-LE series

AC Power Supply PCR-LE2 series

AC Power Supply PCR-M series

Commnunication Interface Mannual


 

OUTP:IMP:RAT

Sets the output impedance in terms of percentage.

This command is valid when the output impedance is on (OUTP:IMP ON).

Command

OUTPut:IMPedance:RATio {<numeric>|MINimum|MAXimum}

OUTPut:IMPedance:RATio? [{MINimum|MAXimum}]

Parameter

Value 1 to 100 (1 by default)
Unit PCT

For the setting that is applied when *RST is sent, see this table

For the setting that is applied when *RST is sent, see this table

For the setting that is applied when *RST is sent, see this table

Response

Response

Returns the output impedance (in terms of percentage) in NR3 format in response to OUTP:IMP:RAT?.