AC Power Supply PCR-LE series

AC Power Supply PCR-LE2 series

AC Power Supply PCR-M series

Commnunication Interface Mannual


 

MEAS:POW:AC:REAC:TOT/ FETC:POW:AC:REAC:TOT

MEAS:POW:AC:REAC:TOT? starts a new measurement and then queries the AC power (the overall reactive power).

FETC:POW:AC:REAC:TOT? queries the AC power (the overall reactive power) without starting a new measurement.

The overall reactive power is calculated from the total of the apparent power of each phase (Stotal) and the total of the active power of each phase (Ptotal).

 

This command is valid in single-phase three-wire output or three-phase output (PCR-LE optional).

The valid modes (parameters to the OUTP:COUP command) are AC.

Command

MEASure[0][:SCALar]:POWer:AC:REACtive:TOTal?

FETCh[0][:SCALar]:POWer:AC:REACtive:TOTal?

Response

Returns the AC power (the overall reactive power) in NR3 format in response to MEAS:POW:AC:REAC:TOT? or FETC:POW:AC:REAC:TOT?.

Unit:VAR

Command (function search)

Command (ABC search)

Command (Sub-system search)

Register

Appendix

Tutorial

AC power supply  PCR-M seriesAC Power Supply PCR-LE series
Communication Interface Manual

AC power supply  PCR-M seriesAC Power Supply PCR-LE2 series
Communication Interface Manual

AC power supply  PCR-M seriesAC Power Supply PCR-M series
Communication Interface Manual