MEAS:POW:AC:PFAC:TOT/ FETC:POW:AC:PFAC:TOT
MEAS:POW:AC:PFAC? starts a new measurement and then queries the total AC power factor.
FETC:POW:AC:PFAC? queries the total AC power factor without starting a new measurement.
This command is valid in single-phase three-wire output or three-phase output (PCR-LE optional).
The valid modes (parameters to the OUTP:COUP command) is AC.
Command
MEASure[0][:SCALar]:POWer:PFACtor:TOTal?
FETCh[0][:SCALar]:POWer:PFACtor:TOTal?
Response
In case of the single-phase three-wire output, returns the total AC power factor of U and V phases in NR3 format in response to MEAS:POW:AC:PFAC:TOT? or FETC:POW:AC:PFAC:TOT?.
In case of the three-phase output, returns the total AC power factor of U, V, and W phases in NR3 format in response to MEAS:POW:AC:PFAC:TOT? or FETC:POW:AC:PFAC:TOT?.