MEAS:CURR:HARM/ FETC:CURR:HARM

MEAS:CURR:HARM? starts a new measurement and then queries the harmonic currents.

FETC:CURR:HARM? queries the harmonic currents without starting a new measurement.

This command is invalid in single-phase three-wire output or three-phase output (PCR-LE optional).

If the EX05-PCR-LE is in use (optional), this command is valid when the signal source is set to internal signal source (FUNC:SOUR INT).

The valid mode (parameter to the OUTP:COUP command) is AC.

Command

MEASure[0][:SCALar]:CURRent:HARMonic?

FETCh[0][:SCALar]:CURRent:HARMonic?

Response

Returns the harmonic currents, from the first to the fortieth, in a comma-separated list of values in NR3 format in response to MEAS:CURR:HARM? or FETC:CURR:HARM?.

Unit:A