AC Power Supply PCR-LE series

AC Power Supply PCR-LE2 series

AC Power Supply PCR-M series

Commnunication Interface Mannual


 

MEAS:CURR:AMPL:MAX:HOLD/ FETC:CURR:AMPL:MAX:HOLD

MEAS:CURR:AMPL:MAX:HOLD? starts a new measurement and then queries the peak current (the held value).

FETC:CURR:AMPL:MAX:HOLD? queries the peak current (the held value) without starting a new measurement.

You can use SENS:CURR:PEAK:CLE to clear the held peak value.

All modes (parameters to the OUTP:COUP command) are valid.

Command

MEASure[0][:SCALar]:CURRent:AMPLitude:MAXimum:HOLD?

FETCh[0][:SCALar]:CURRent:AMPLitude:MAXimumv:HOLD?

Response

Returns the peak current (the held value) in NR3 format in response to MEAS:CURR:AMPL:MAX:HOLD? or FETC:CURR:AMPL:MAX:HOLD?.

In case of the single-phase three-wire output, MEAS:CURR:AMPL:MAX:HOLD? or FETC:CURR:AMPL:MAX:HOLD? returns a comma-separated list of the peak current (the held value) <NR3> for U and V phases.

In case of the three-phase output, MEAS:CURR:AMPL:MAX:HOLD? or FETC:CURR:AMPL:MAX:HOLD? returns a comma-separated list of the peak current (the held value) <NR3> for U, V, and W phases.

Unit:A

Command (function search)

Command (ABC search)

Command (Sub-system search)

Register

Appendix