MEAS:CURR:AMPL:MAX:HOLD/ FETC:CURR:AMPL:MAX:HOLD
MEAS:CURR:AMPL:MAX:HOLD? starts a new measurement and then queries the peak current (the held value).
FETC:CURR:AMPL:MAX:HOLD? queries the peak current (the held value) without starting a new measurement.
You can use SENS:CURR:PEAK:CLE to clear the held peak value.
All modes (parameters to the OUTP:COUP command) are valid.
Command
MEASure[0][:SCALar]:CURRent:AMPLitude:MAXimum:HOLD?
FETCh[0][:SCALar]:CURRent:AMPLitude:MAXimumv:HOLD?
Response
Returns the peak current (the held value) in NR3 format in response to MEAS:CURR:AMPL:MAX:HOLD? or FETC:CURR:AMPL:MAX:HOLD?.
In case of the single-phase three-wire output, MEAS:CURR:AMPL:MAX:HOLD? or FETC:CURR:AMPL:MAX:HOLD? returns a comma-separated list of the peak current (the held value) <NR3> for U and V phases.
In case of the three-phase output, MEAS:CURR:AMPL:MAX:HOLD? or FETC:CURR:AMPL:MAX:HOLD? returns a comma-separated list of the peak current (the held value) <NR3> for U, V, and W phases.
Unit:A