AC Power Supply PCR-LE series

AC Power Supply PCR-LE2 series

AC Power Supply PCR-M series

Commnunication Interface Mannual


 

MEAS{1|2|3}:VOLT:AMPL:MAX/ FETC{1|2|3}:VOLT:AMPL:MAX

MEAS{1|2|3}:VOLT:AMPL:MAX? starts a new measurement and then queries the peak voltage of the specified phase.

FETC{1|2|3}:VOLT:AMPL:MAX? queries the peak voltage of the specified phase without starting a new measurement.

This command is valid in single-phase three-wire output or three-phase output (PCR-LE optional).

The valid modes (parameters to the OUTP:COUP command) is AC.

Command

U phase

MEASure1[:SCALar]:VOLTage:AMPLitude:MAXimum?

FETCh1[:SCALar]:VOLTage:AMPLitude:MAXimum?

V phase

MEASure2[:SCALar]:VOLTage:AMPLitude:MAXimum?

FETCh2[:SCALar]:VOLTage:AMPLitude:MAXimum?

W phase (Three-phase output only)

MEASure3[:SCALar]:VOLTage:AMPLitude:MAXimum?

FETCh3[:SCALar]:VOLTage:AMPLitude:MAXimum?

Response

Returns the peak voltage of U phase in NR3 format in response to MEAS1:VOLT:AMPL:MAX? or FETC1:VOLT:AMPL:MAX?.

Returns the peak voltage of V phase in NR3 format in response to MEAS2:VOLT:AMPL:MAX? or FETC2:VOLT:AMPL:MAX?.

Returns the peak voltage of W phase in NR3 format in response to MEAS3:VOLT:AMPL:MAX? or FETC3:VOLT:AMPL:MAX?.

Unit: V

Command (function search)

Command (ABC search)

Command (Sub-system search)

Register

Appendix

Tutorial

AC power supply  PCR-M seriesAC Power Supply PCR-LE series
Communication Interface Manual

AC power supply  PCR-M seriesAC Power Supply PCR-LE2 series
Communication Interface Manual

AC power supply  PCR-M seriesAC Power Supply PCR-M series
Communication Interface Manual