MEAS{1|2|3}:CURR:AC/ FETC{1|2|3}:CURR:AC
MEAS{1|2|3}:CURR:AC? starts a new measurement and then queries the AC current of the specified phase.
FETC{1|2|3}:CURR:AC? queries the AC current of the specified phase without starting a new measurement.
This command is valid in single-phase three-wire output or three-phase output (PCR-LE optional).
The valid modes (parameters to the OUTP:COUP command) is AC.
Command
U phase
MEASure1[:SCALar]:CURRent:AC?
FETCh1[:SCALar]:CURRent:AC?
V phase
MEASure2[:SCALar]:CURRent:AC?
FETCh2[:SCALar]:CURRent:AC?
W phase (Three-phase output only)
MEASure3[:SCALar]:CURRent:AC?
FETCh3[:SCALar]:CURRent:AC?
Response
Returns the AC current of U phase in NR3 format in response to MEAS1:CURR:AC? or FETC1:CURR:AC?.
Returns the AC current of V phase in NR3 format in response to MEAS2:CURR:AC? or FETC2:CURR:AC?.
Returns the AC current of W phase in NR3 format in response to MEAS3:CURR:AC? or FETC3:CURR:AC?.
Unit: A