AC Power Supply PCR-LE series

AC Power Supply PCR-LE2 series

AC Power Supply PCR-M series

Commnunication Interface Mannual


 

SENS:HOLD

Sets the hold time of the peak current.

Command

SENSe:HOLD {SHORt|LONG}

SENSe:HOLD?

Parameter

Value SHORt Update every approximately 0.3 seconds (default)
  LONG Hold the peak value for approximately 5 seconds

Response

Returns the hold time of the peak current in CHAR format in response to SENS:HOLD?.

Command (function search)

Command (ABC search)

Command (Sub-system search)

Register

Appendix

Tutorial

AC power supply  PCR-M seriesAC Power Supply PCR-LE series
Communication Interface Manual

AC power supply  PCR-M seriesAC Power Supply PCR-LE2 series
Communication Interface Manual

AC power supply  PCR-M seriesAC Power Supply PCR-M series
Communication Interface Manual