AC Power Supply PCR-LE series

AC Power Supply PCR-LE2 series

AC Power Supply PCR-M series

Commnunication Interface Mannual


 

OUTP:SST:TIME

Sets the soft start rise time.

This command is valid when soft starts are on (OUTP:SST ON).

Command

OUTPut:SSTart:TIME[:RISE] {<numeric>|MINimum|MAXimum}

OUTPut:SSTart:TIME[:RISE]? [{MINimum|MAXimum}]

Parameter

Value 0.1 to 3.0 (0.1 by default)
Unit S

For the setting that is applied when *RST is sent, see this table

For the setting that is applied when *RST is sent, see this table

For the setting that is applied when *RST is sent, see this table

Response

Response

Returns the rise time in NR3 format in response to OUTP:SST:TIME?.

Command (function search)

Command (ABC search)

Command (Sub-system search)

Register