AC Power Supply PCR-LE series

AC Power Supply PCR-LE2 series

AC Power Supply PCR-M series

Commnunication Interface Mannual


 

MEM:PREV

Views the settings that are stored in memory.

Command

MEMory:PREView? <NRf>

Parameter

Value 0 to 99 Memory No.

Response

Returns the following items that are stored at the specified memory entry number. The items are returned in the following order as a comma-separated list in response to MEM:PREV? <NRf>.

Memory entry number <NR1>,AC voltage <NR3>,DC voltage <NR3>,frequency <NR3>,waveform bank number <NR1>

In case of the single-phase three-wire output, Memory entry number <NR1>,AC voltage of U phase<NR3>,AC voltage of V phase<NR3>,DC voltage of U phase<NR3>,DC voltage of V phase<NR3>,frequency <NR3>,waveform bank number <NR1>

In case of the three-phase output, Memory entry number <NR1>,AC voltage of U phase<NR3>,AC voltage of V phase<NR3>,AC voltage of W phase<NR3>,DC voltage of U phase<NR3>,DC voltage of V phase<NR3>,DC voltage of W phase<NR3>,frequency <NR3>,waveform bank number <NR1>

Command (function search)

Command (ABC search)

Command (Sub-system search)

Register

Appendix

Tutorial

AC power supply  PCR-M seriesAC Power Supply PCR-LE series
Communication Interface Manual

AC power supply  PCR-M seriesAC Power Supply PCR-LE2 series
Communication Interface Manual

AC power supply  PCR-M seriesAC Power Supply PCR-M series
Communication Interface Manual