AC Power Supply PCR-LE series

AC Power Supply PCR-LE2 series

AC Power Supply PCR-M series

Commnunication Interface Mannual


 

OPERation:INSTrument:ISUMmary{1|2|3} subregister

This is the subregister of bit 1 to bit 3 of the OPERation:INSTrument subregister. This is a 16-bit register that contains information about the normal operating conditions of the PCR-LE/PCR-LE2 Series

Of the parameters {1|2|3}, 1 represents U phase, 2 represents V phase, and 3 represents W phase.

For example, V phase is specified as "OPER:INST:ISUM2".

 

Bit Bit weight Bit name Description
0 1 NOT USED --
1 2 NOT USED --
2 4 NOT USED --
3 8 NOT USED --
4 16 MEASuring Indicates whether measurement is in progress on the PCR-LE/PCR-LE2.
5 32 Waiting for TRIGger Indicates whether measurement is in progress on the PCR-LE/PCR-LE2.
6 64 NOT USED --
7 128 BUSY The period when the PCR-LE/PCR-LE2 is returning from sleep mode or when the output cannot be turned on after an OCP2 or OC has occurred
8 256 CV CV output
9 512 NOT USED --
10 1024 SYNC Indicates whether the synchronization function is in operation.
11 2048 SIMuration Indicates whether a power line abnormality simulation is being performed.
12 4096 RISE Indicates whether a soft start is being performed.
13 8192 INSTrument Summary --
14 16384 PROGram Indicates whether a sequence is being performed.
15 32768 NOT USED Always zero

>top

Command (function search)

Command (ABC search)

Command (Sub-system search)

Register

Appendix

Tutorial

AC power supply  PCR-M seriesAC Power Supply PCR-LE series
Communication Interface Manual

AC power supply  PCR-M seriesAC Power Supply PCR-LE2 series
Communication Interface Manual

AC power supply  PCR-M seriesAC Power Supply PCR-M series
Communication Interface Manual