Command (function search)
Setting the Protection Function and Clearing the Alarm
Overcurrent protection (OCP)
CURR:PROT | Sets the current in OCP |
---|---|
CURR:PROT:STAT | Sets the operation of the PLZ12005WH/PLZ20005WH when OCP is activated |
Overpower protection (OPP)
POW:PROT | Sets the power in OPP |
---|---|
POW:PROT:STAT | Sets the operation of the PLZ12005WH/PLZ20005WH when OPP is activated |
Undervoltage protection (UVP)
VOLT:PROT:LOW | Sets the voltage of UVP |
---|---|
VOLT:PROT:STAT | Enables/disables UVP |
VOLT:PROT:ACT | Sets the operation of the PLZ12005WH/PLZ20005WH when UVP is activated |
Overcurrent protection (OCP) during program operation
PROG:CURR:PROT | Sets the current value of OCP for program operation |
---|---|
PROG:CURR:PROT:STAT PROG:CURR:PROT:ACT | Sets how the PLZ12005WH/PLZ20005WH operates when OCP is activated during program operation |
Overpower protection (OPP) during program operation
PROG:POW:PROT | Sets the power value of OPP for program operation |
---|---|
PROG:POW:PROT:STAT PROG:POW:PROT:ACT |
Sets how the PLZ12005WH/PLZ20005WH operates when OPP is activated during program operation |
Undervoltage protection (UVP) for program operation
PROG:VOLT:PROT:LOW | Sets the voltage value of UVP for program operation |
---|---|
PROG:VOLT:PROT:STAT | Enables or disables UVP for program operation |
PROG:VOLT:PROT:ACT | Sets how the PLZ12005WH/PLZ20005WH operates when UVP is activated during program operation |
Clears alarms
INP:PROT:CLE OUTP:PROT:CLE |
Clears alarms |
---|