PLZ12005WH/PLZ20005WH Electronic Load

Commnunication Interface Mannual


 

PROG:STEP<n>:TRIG:WAIT

Sets trigger wait at the specified step of the program selected by PROG.

Command

[SOURce:]PROGram[:SELected]:STEP<n>:TRIGger:WAIT <character>[,<character>,<character>]

[SOURce:]PROGram[:SELected]:STEP<n>:TRIGger:WAIT?

Parameter <n>

Value Specifies the step number
Example STEP1

Parameter <character>

If IMMediate or BUS is set, it cannot be specified at the same time as other setting values.
You can specify up to 3 items in the case of TRIGIN, DIGITAL2 and MSYNc.

Value IMMediate Execution the step at the internal timing of the PLZ12005WH/PLZ20005WH without waiting for trigger application
BUS Executes the step at the timing of software trigger (*TRG) application. The trigger is applied to both trigger systems: (1) sequence and step (TRANsient) and (2) measure (ACQuire).
TRIGIN Executes the step at the timing at which a signal is input to pin 9 of the EXT CONT connector of the PLZ12005WH/PLZ20005WH
DIGITAL2 Executes the step at the timing at which a signal is input to pin 13 of the EXT CONT connector of the PLZ12005WH/PLZ20005WH (when SYST:CONF:DIGITAL2:DIR is set to INPut)
MSYNc A step is executed when a signal (ACQuire command) is received from external equipment synchronized to the PLZ12005WH/PLZ20005WH or when a TRIG:ACQ:MSYN synchronization command packet is received from a PC or the like.

Example

PROG:STEP1:TRIG:WAIT DIGITAL2,MSYNc

Response

Returns the trigger wait setting state at the specified step in character format in response to the PROG:STEP<n>:TRIG:WAIT? query.