PLZ12005WH/PLZ20005WH Electronic Load

Commnunication Interface Mannual


 

FETC:POW?
READ:POW?
MEAS:POW?

Queries the measured power (W) Each command is different in the following ways.

  • FETC? does not wait for the measurement to finish. It queries the most recent measured value when the command is received. If there is no measured value, the measured value is queried after waiting for the completion of a single measurement. If TRIG:ACQ:SOUR is set to BUS, an error is returned.
  • READ? starts a new measurement and queries the measured value after waiting for the completion of a single measurement. If TRIG:ACQ:SOUR is set to IMM, measurement starts immediately. If set to BUS, an error is returned. If set to any other value, measurement starts after a trigger is applied.
  • MEAS? starts a new measurement after resetting (equivalent to *RST) the settings listed in “Setting Measurement Conditions,” and queries a single measured value.

Command

FETCh:POWer[:DC]?

READ:POWer[:DC]?

MEASure:POWer[:DC]?

Response

Returns the power (W) in NR3 format in response to the FETC:POW?, READ:POW? or MEAS:POW? query.

Setup

Overview of Command

Command (function search)

Command (ABC search)

Command (Sub-system search)

Register

Appendix

Tutorial

Electronic Load  PLZ12005WH/PLZ20005WHElectronic Load PLZ12005WH/PLZ20005WH
Communication Interface Manual