COND:PULS:FREQ
Sets the pulse frequency. (Alias for CURR:PULS:FREQ)
This frequency is used in common for CURRent and CONDuctance pulse.
Command
[SOURce:]CONDuctance[:LEVel]:PULSe:FREQuency {<numeric>|MINimum|MAXimum}
[SOURce:]CONDuctance[:LEVel]:PULSe:FREQuency? [{MINimum|MAXimum}]
Parameter
Setting range | 1.0 to 10.0k | ||
---|---|---|---|
Resolution | 1 to 10 | 0.1 | |
11 to 100 | 1 | ||
110 to 1000 | 10 | ||
1.1k to 10.0k | 0.1k | ||
Unit | Hz | ||
*RST transmission | 1 |
Response
Returns the pulse frequency in NR3 format in response to the COND:PULS:FREQ? query.
(Reference) The period resolution ⊿T is set to 1 [μs] in the device. The response returns the inverse of the period set in the device. For example, if you specify 9300 Hz, 108 [μs] is set in the device. The response in this situation will be 9259.26Hz.