PLZ12005WH/PLZ20005WH Electronic Load

Commnunication Interface Mannual


 

PROG:STEP<n>:LEV

Sets the load at the specified step of the program selected by PROG.

Command

[SOURce:]PROGram[:SELected]:STEP<n>:LEVel <numeric>

[SOURce:]PROGram[:SELected]:STEP<n>:LEVel?

Parameter <n>

Value Specifies the step number
Example STEP1

Parameter <numeric>

See the references below according to the present operation mode

Current (Unit: A)

Conductance (Unit: SIE)

Voltage (Unit: V)

Power (Unit: W)

Response

Returns the load at the specified step in NR3 format in response to the PROG:STEP<n>:LEV? query.

Setup

Overview of Command

Command (function search)

Command (ABC search)

Command (Sub-system search)

Register

Appendix

Tutorial

Electronic Load  PLZ12005WH/PLZ20005WHElectronic Load PLZ12005WH/PLZ20005WH
Communication Interface Manual