PROG:STEP<n>:DWEL

Sets the step execution time at the specified step of the program selected by PROG.

Command

[SOURce:]PROGram[:SELected]:STEP<n>:DWELl <numeric>

[SOURce:]PROGram[:SELected]:STEP<n>:DWELl?

Parameter <n>

Value Specifies the step number
Example STEP1

Parameter <numeric>

Value 50u to 3600000
Resolution 1u
Unit S

Response

Returns the execution time at the specified step in NR3 format in response to the PROG:STEP<n>:DWEL? query.