INP:CUTO:VOLT
OUTP:CUTO:VOLT

Sets the voltage drop of the cutoff function.

Command

INPut:CUTOff:VOLTagel:[:LEVel][:LOWer] {<numeric>|MINimum|MAXimum}

OUTPut:CUTOff:VOLTagel:[:LEVel][:LOWer] {<numeric>|MINimum|MAXimum}

INPut:CUTOff:VOLTagel:[:LEVel][:LOWer]? {MINimum|MAXimum}

OUTPut:CUTOff:VOLTagel:[:LEVel][:LOWer]? {MINimum|MAXimum}

Parameter

Value 0.00 to 800.00
Resolution 0.02
Unit V
*RST transmission 0

Response

Returns the voltage drop value in NR3 format in response to the INP:CUTO:VOLT? or OUTP:CUTO:VOLT? query.